Performance Features
At YORK®, comfort is more than a feeling – it's a promise: to innovate, to assure and, most of all, to deliver. Find out how we leverage our unparalleled residential dealer network and world-class commercial support services to lead the industry. View & download of more than 1614 McQuay PDF user manuals, service manuals, operating guides. Air Conditioner, Chiller user manuals, operating guides & specifications. Need for speed carbon download mac.
- IPLV to 0.299
- Chlorine-free HFC-134a refrigerant
- Full Load kW/Ton to 0.53
- Tri-rotor, positive displacement screw compressor
- Hermetic compressor motor
- Refrigerant-cooled, unit-mounted variable frequency drive
- Low inrush current
- Operation of up to 0.99 power factor
- Flooded shell-and-tube cooler
- Float valve
- Superior oil management/cold condenser water operation
- Internally and externally enhanced 0.025 in. (0.635 mm) copper tubing
- 150 psig (1034 kPa) rated cooler and condenser
- LCD control display
- Microprocessor-based Product Integrated Control (PIC) III
- Multilingual display
- Demand limiting capability with Carrier Comfort Network® (CCN) communication link
Contract administration. For the maintenance of HVAC Systems in Australia, the availability of the AIRAH application manual DA19 – HVAC&R Maintenance is acknowledged. This Guide focuses on energy and water effi ciency aspects of maintenance and operation, complementing the advice and maintenance schedules already published in DA19. And Maintenance Manual The Arctic Chiller Group Part #9800-0100 Publication # PAC-001.02 October, 2018 ArctiChill. 71 Industrial Park Road Newberry, South Carolina 29108 Manhattan Modular Air-Cooled Chiller. Installation, Operation, and Maintenance Manual Manhattan Modular. Sep 04, 2020 With HVAC.com, you can quickly find the HVAC manual you need to help with product installation, maintenance, repair, warranty, or technical information!
Reliability Features
- ASME constructed heat exchangers
- PED/CE construction option
- Low voltage control circuits
- Lowest industry refrigerant leakage rate at less than 0.1%
- Hermetically sealed compressor motor
- Automated controls may be tested before start-up
- 65K AIC circuit breaker
Maintenance Features
- Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
- Alarm and alert files maintain the last 25 time and date stamped messages in memory
- Configuration data backup with non-volatile memory
- Refrigerant filter isolation valves
- Thermistor type temperature sensor with quick connects in each water nozzle
- Service contract available
![Maintenance Maintenance](/uploads/1/2/6/3/126368006/996410078.png)
Installation Features
- Modular construction
- Single point electrical connection
- Can be dismantled and reassembled
- Unit-mounted VFD with single point connection
- Small footprint
Standard Warranty
- One year from start-up or 18 months from shipment
- Refrigerant warranty 5 years from date of manufacture
- Extended warranties available
Factory-Installed Options
- Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
- Internally/externally enhanced copper tubing - cooler/condenser
- Internally/externally enhanced cupronickel tubing - condenser
- Smooth bore/externally enhanced copper tubing - cooler/condenser
- Smooth bore/externally enhanced cupronickel tubing - condenser
- Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
- Internally enhanced tubes
- Smooth bore tubes
- Marine waterboxes (available for heat exchanger frames 3-5 only):
- 150 psig (1034 kPa) waterbox
- 300 psig (2068 kPa) waterbox
- Nozzle-in-head waterbox, 300 psig (2068 kPa)
- Hinged waterboxes
- Flanged cooler and/or condenser waterbox nozzles
- One, 2, or 3 pass cooler or condenser waterside construction
- Zinc anodes
- 100K AIC high interrupt circuit breaker with shunt trip
- Analog voltmeter and ammeter with 3-phase selector switch
- DataLINK™ or DataPort™ communication device
- Shipped factory charged with refrigerant
- Hot gas bypass
- Full cold surface thermal insulation (except waterbox covers)
- Customer factory performance testing
- Export crating
Field-Installed Accessories
- BACnet™ Carrier translator
- DataLINK™ or DataPort™ communication device
- LonWorks® Carrier translator
- Sensor package
- Separate storage tank and pumpout unit
- Stand-alone pumpout unit
- Soleplate package
- Spring isolator kit
- Refrigerant isolation valves for in-chiller refrigerant storage
- Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing
- Acoustical sound insulation kit
- Shipped fully charged
Nominal Capacity (Tons)* | Heat Exchanger Size | Length with Nozzle-in-Head Waterbox | Width | Height | |||||
---|---|---|---|---|---|---|---|---|---|
2-Pass** | 1 or 3-Pass | ||||||||
ft-in | mm | ft-in | mm | ft-in | mm | ft-in | mm | ||
250-550 | 30 to 32 | 13-8¼ | 4172 | 14-3¼ | 4350 | See Unit Certified Drawings | See Unit Certified Drawings | ||
35 to 37 | 15-4¾ | 4693 | 15-11¾ | 4870 | |||||
40 to 42 | 14-3 1⁄8 | 4347 | 14-9 | 4496 | |||||
45 to 47 | 15-11 5⁄8 | 4867 | 16-5½ | 5017 | |||||
50 to 52 | 14-4½ | 4382 | 14-10 | 4521 | |||||
55 to 57 | 16-1 | 4902 | 16-6½ | 5042 |
*For job specific dimensions and weight information, please contact your Carrier Sales Representative.
**Assumes all customer connections are on the same end of the chiller.
Performance Features
Multistack Chiller Maintenance Manual
- IPLV to 0.299
- Chlorine-free HFC-134a refrigerant
- Full Load kW/Ton to 0.53
- Tri-rotor, positive displacement screw compressor
- Hermetic compressor motor
- Refrigerant-cooled, unit-mounted variable frequency drive
- Low inrush current
- Operation of up to 0.99 power factor
- Flooded shell-and-tube cooler
- Float valve
- Superior oil management/cold condenser water operation
- Internally and externally enhanced 0.025 in. (0.635 mm) copper tubing
- 150 psig (1034 kPa) rated cooler and condenser
- LCD control display
- Microprocessor-based Product Integrated Control (PIC) III
- Multilingual display
- Demand limiting capability with Carrier Comfort Network® (CCN) communication link
Reliability Features
Arctic Chiller Maintenance Manual
![Chiller Chiller](/uploads/1/2/6/3/126368006/303726166.jpg)
- ASME constructed heat exchangers
- PED/CE construction option
- Low voltage control circuits
- Lowest industry refrigerant leakage rate at less than 0.1%
- Hermetically sealed compressor motor
- Automated controls may be tested before start-up
- 65K AIC circuit breaker
Maintenance Features
- Password protected extensive service menu with built-in diagnostic capabilities, troubleshooting, and corrective action recommendations for preset alarms
- Alarm and alert files maintain the last 25 time and date stamped messages in memory
- Configuration data backup with non-volatile memory
- Refrigerant filter isolation valves
- Thermistor type temperature sensor with quick connects in each water nozzle
- Service contract available
Installation Features
- Modular construction
- Single point electrical connection
- Can be dismantled and reassembled
- Unit-mounted VFD with single point connection
- Small footprint
Standard Warranty
- One year from start-up or 18 months from shipment
- Refrigerant warranty 5 years from date of manufacture
- Extended warranties available
Factory-Installed Options
- Enhanced tubing, .028 or .035 in. (0.711 or 0.889 mm):
- Internally/externally enhanced copper tubing - cooler/condenser
- Internally/externally enhanced cupronickel tubing - condenser
- Smooth bore/externally enhanced copper tubing - cooler/condenser
- Smooth bore/externally enhanced cupronickel tubing - condenser
- Wall tubes, titanium, condenser, .025 or .028 in. (0.635 or 0.711 mm):
- Internally enhanced tubes
- Smooth bore tubes
- Marine waterboxes (available for heat exchanger frames 3-5 only):
- 150 psig (1034 kPa) waterbox
- 300 psig (2068 kPa) waterbox
- Nozzle-in-head waterbox, 300 psig (2068 kPa)
- Hinged waterboxes
- Flanged cooler and/or condenser waterbox nozzles
- One, 2, or 3 pass cooler or condenser waterside construction
- Zinc anodes
- 100K AIC high interrupt circuit breaker with shunt trip
- Analog voltmeter and ammeter with 3-phase selector switch
- DataLINK™ or DataPort™ communication device
- Shipped factory charged with refrigerant
- Hot gas bypass
- Full cold surface thermal insulation (except waterbox covers)
- Customer factory performance testing
- Export crating
Carrier Chiller Maintenance Manual
Field-Installed Accessories
- BACnet™ Carrier translator
- DataLINK™ or DataPort™ communication device
- LonWorks® Carrier translator
- Sensor package
- Separate storage tank and pumpout unit
- Stand-alone pumpout unit
- Soleplate package
- Spring isolator kit
- Refrigerant isolation valves for in-chiller refrigerant storage
- Unit-mounted pumpout unit for storing refrigerant inside the chiller during servicing
- Acoustical sound insulation kit
- Shipped fully charged
Nominal Capacity (Tons)* | Heat Exchanger Size | Length with Nozzle-in-Head Waterbox | Width | Height | |||||
---|---|---|---|---|---|---|---|---|---|
2-Pass** | 1 or 3-Pass | ||||||||
ft-in | mm | ft-in | mm | ft-in | mm | ft-in | mm | ||
250-550 | 30 to 32 | 13-8¼ | 4172 | 14-3¼ | 4350 | See Unit Certified Drawings | See Unit Certified Drawings | ||
35 to 37 | 15-4¾ | 4693 | 15-11¾ | 4870 | |||||
40 to 42 | 14-3 1⁄8 | 4347 | 14-9 | 4496 | |||||
45 to 47 | 15-11 5⁄8 | 4867 | 16-5½ | 5017 | |||||
50 to 52 | 14-4½ | 4382 | 14-10 | 4521 | |||||
55 to 57 | 16-1 | 4902 | 16-6½ | 5042 |
Auto mastering plugin. *For job specific dimensions and weight information, please contact your Carrier Sales Representative.
York Chiller Maintenance Manual
**Assumes all customer connections are on the same end of the chiller.